Manuals answer how to install, start and service; charts answer how large. Both are arranged here by series and open directly, with no download.
The online versions are edited from the original files: chapter structure and technical wording are kept, only paragraphing and punctuation are adjusted. For pressure, lifting and electrical work, the supplied documents and written confirmation still govern.

Series first, document second: identify the pump family, then open its manual.
| Manual | Series covered | Note |
|---|---|---|
| AH / L / G Series Manual | AH Series Heavy Duty Slurry Pump, HH Series High Head Slurry Pump, L Series Light Duty Slurry Pump, DT Series Desulphurisation Pump, G / GH Gravel Pump, AF Series Froth Pump | Primarily AH, L and G, with the same requirements applying to the HH, DT and AF horizontal builds; the most complete of the five. |
| SP Series Sump Pump Manual | SP / SPR Vertical Sump Pump | Sump pumps only: submergence, shaft length, rotation and the ban on low-flow running. |
| ZJ Series Pump Manual | ZJ Series Slurry Pump, SYA / ZJE Filter Press Feed Pump, ZJL Series Vertical Slurry Pump, ZJQ Submersible Slurry Pump | ZJ at the core; SYA/ZJE, ZJL and ZJQ share the same assembly sequence and clearance requirements. |
| ZGB Series Pump Manual | ZGB Series Slurry Pump, 300LPT-SHG Shield Mud Pump | Expeller sealing and multi-stage requirements for ash duty; the 300LPT-SHG refers to it as well. |
| G Gravel Pump Manual | G / GH Gravel Pump, 300LPT-SHG Shield Mud Pump | Single-casing gravel pump, scanned page by page so figure numbers can be matched. |
A manual is not meant to be read cover to cover. Look it up by the problem in front of you.
| Chapter | What it covers | When to look |
|---|---|---|
| Overview and scope | Confirms whether the pump suits the medium and installation, and whether it may be staged. | When taking over an unfamiliar pump |
| Construction | Shows how casing, liners, frame and seal fit together, so disassembly follows the right order. | Before disassembly |
| Assembly and installation | Bearing preheat limits, wet-end assembly sequence, pipework and alignment requirements. | During installation and piping |
| Shaft seal and lubrication | Where packing, expeller and mechanical seals apply, plus seal water pressure, flow and grease. | When adjusting packing or seal water |
| Start-up and operation | Rotation check, priming, valve sequence and the checks to make while running. | At first start-up and shift handover |
| Maintenance and faults | Service levels, wear-part replacement criteria and the order to work through faults. | When vibration, leakage or flow loss appears |
Excerpts from the original text, grouped by series; open the reading page for the full clause.
The fractional AH designation uses inlet / outlet diameters in inches (6/4 means a 6 inch inlet and 4 inch outlet). The casing registers on the frame and the discharge can be installed in eight positions.
Read the full clause in the manual →
ZGB(P) pumps are horizontal, single-stage, single-suction, overhung double-casing centrifugal pumps. The suction is horizontal and rotation is clockwise viewed from the drive end; reverse rotation must never be allowed.
Read the full clause in the manual →
SP(R) pumps are vertical centrifugal slurry pumps working immersed in a pit or sump. SP uses metal wetted parts and shaft; SPR has rubber-lined immersed components.
Read the full clause in the manual →
Maximum slurry concentration by weight for ZJ pumps: 45 percent for ash / coal slurry and 60 percent for ore slurry and heavy medium.
Read the full clause in the manual →
D dredge and G gravel pumps have large passages for gravel, mud and coarse solids. They use a single casing without liners, with casing, cover and impeller all in wear-resistant metal.
Read the full clause in the manual →
Charts give ranges, not guarantees. Firm selection needs a hydraulic check, and the supplied documents govern.
| Document | Contents |
|---|---|
| AH Series Pump Performance Chart | Clear-water performance, motor and outline dimensions |
| SP Series Vertical Pump Chart | Clear-water performance, motor and outline dimensions |
| ZJ Series Pump Performance Chart | Clear-water performance, motor and outline dimensions |
| ZJL Series Vertical Pump Chart | Clear-water performance, motor and outline dimensions |
| DT Series Pump Performance Chart | Clear-water performance, motor and outline dimensions |
| ZJE Filter Press Feed Pump Chart | Clear-water performance, motor and outline dimensions |
| Pump Type Catalogue | All series and models at a glance |
Use the manual for the same series: construction, assembly and sealing requirements carry across. For differences such as impeller diameter, frame or stage count, send a nameplate photo.
The web version prints from the browser. For DOC or PDF originals for submissions or delivery documentation, contact us.
The supplied documents and written confirmation govern. The web copies serve selection and field reference, not acceptance.
The manual for that series, paying attention to pressure and seal water changes with stage count. ZGB staged units have a dedicated section.
The drawings section of the technical support page holds construction drawings, dimension sheets and reference covers, all zoomable.
Tell us the model and the purpose (submission, delivery documents or site service) and we send the matching file.
We reply within one business day. You can also call +86 188 0321 2220.
Please provide the pump model, nameplate data and duty parameters by phone or email. Performance charts and manuals can be read online.