Fractional designations such as 6/4 and 8/6 are the shared language of the AH range: suction and discharge bores in inches. The series is designed for abrasive, high-density slurry as normal duty, with replaceable liners inside the casing and cover plate and frames sized by load.
Construction, model range, wetted materials and duty limits for this series. Figures come from the charts and manuals on file; values not published are marked "per supplied documents".

Horizontal, overhung, double-casing centrifugal slurry pump. The AH series is the heavy-duty member of the fractional slurry pump family. Replaceable metal or rubber liners sit inside the casing and cover plate, wear sections are thickened and the frames carry high loads. It is used for continuous abrasive, high-concentration slurry duty and may be staged in series within its allowable working pressure.
For example 6/4D-AH: 6 is the suction bore (inch), 4 the discharge bore (inch), D the frame code and AH the heavy-duty series; a trailing R denotes rubber lining.
Typical coverage: discharge bores about 25-450 mm, flow up to about 8600 m3/h and single-stage head up to about 68 m.
| Model | Max. power kW | Q m³/h | H m | n r/min | Max. eff. % |
|---|---|---|---|---|---|
| 1.5/1B-AH | 15 | 12.6-28.8 | 6-68 | 1200-3800 | 40 |
| 2/1.5B-AH | 15 | 32.4-72 | 6-58 | 1200-3200 | 45 |
| 3/2C-AH | 30 | 39.6-86.4 | 12-64 | 1300-2700 | 55 |
| 4/3C-AH | 30 | 86.4-198 | 9-52 | 1000-2200 | 71 |
| 4/3D-AH | 60 | 86.4-198 | 9-52 | 1000-2200 | 71 |
| 6/4D-AH | 60 | 162-360 | 12-56 | 800-1550 | 65 |
| 6/4E-AH | 120 | 162-360 | 12-56 | 800-1550 | 65 |
| 8/6E-AH | 120 | 360-828 | 10-61 | 500-1140 | 72 |
| 8/6R-AH | 300 | 360-828 | 10-61 | 500-1140 | 72 |
| 10/8ST-AH | 560 | 612-1368 | 11-61 | 400-850 | 71 |
| 12/10ST-AH | 560 | 936-1980 | 7-68 | 300-800 | 82 |
| 14/12ST-AH | 560 | 1260-2772 | 13-63 | 300-600 | 77 |
The industry pages behind these duties set out recommended series, wear parts and field checks.
Material follows the medium; sealing follows suction pressure and whether dilution is allowed.
Each part page lists the basic number, material options and applicable models. One basic number maps to different part numbers across frames, so check against the nameplate.

Mainly high-chrome wear alloy (A05 / Cr26 / Cr27); rubber or p…

High-chrome wear alloy, wear-resistant rubber or polyurethane:…

High-chrome wear alloy, rubber lining or wear/corrosion-resist…

High-chrome wear alloy or rubber; metal parts are preferred fo…

Wear-resistant alloy, stainless or 3Cr13-type martensitic stee…

High-chrome wear alloy or wear-resistant rubber, matched to th…
Excerpts that apply to this series; read the full text on the online reading page.
A trailing R marks rubber-lined wetted parts (for example 6/4D-AHR); without R the wetted parts are metal. Casing, frame and mounting dimensions are the same; the difference is material and the media each suits.
6 is a 6 inch suction bore, 4 a 4 inch discharge bore, D is the frame code and AH the series. The fraction says nothing about flow; read the model chart for that.
Use the maximum passing particle size in each model chart. When solids approach the impeller passage width, move to the wide-passage single-casing G gravel pump instead of enlarging the AH size.
Send the medium, particle size and solids content, flow, head, pH and temperature, plus installation conditions (pit depth or line length). For parts, add the pump model or a photo of the worn part.
We reply within one business day. You can also call +86 188 0321 2220.
Please provide the pump model, nameplate data and duty parameters by phone or email. Performance charts and manuals can be read online.