The AH series is the heavy-duty member of the fractional slurry pump family. Replaceable metal or rubber liners sit inside the casing and cover plate, wear sections are thickened and the frames carry high loads. It is used for continuous abrasive, high-concentration slurry duty and may be staged in series within its allowable working pressure.

Horizontal Slurry PumpHorizontal, overhung, double-casing centrifugal slurry pumpFrame D
86.4–198Capacity Q m³/h
9–52Head H m
1000–2200Speed r/min
MODEL CODE

Reading the code 4/3D-AH

Each segment explained against published industry naming conventions.

FieldMeaning
Suction bore4 in
Discharge bore3 in
Frame codeD (commonly published max. motor power about 60 kW)
Series codeAH
Model codes are explained against common industry naming conventions for reading the letters and numbers only. Bore sizes, frames, materials and performance of a specific build follow the supplied documents and written confirmation.
CONSTRUCTION & DUTIES

Construction and typical duties

AH Series Heavy Duty Slurry Pump

Construction

01

Double casing: an outer pressure shell plus replaceable wear liners that can run until worn through.

02

The discharge can be rotated in 45 degree increments to match site pipework.

03

A cartridge bearing assembly can be removed as a unit and allows impeller-to-liner clearance adjustment.

04

Wetted parts are available in high-chrome wear alloy or rubber lining; metal and rubber builds are interchangeable on some sizes.

Typical duties

01

Cyclone feed, ball/rod mill discharge

02

Concentrate, tailings and hydraulic transport

03

Coal washing, ash handling and metallurgical slurry

Construction drawing
Slurry pump construction drawing
MATERIALS & SEALS

Wetted materials and shaft seals

Wetted materials

High-chrome wear alloys (often A05 / Cr26 / Cr27) for angular, highly abrasive solids; natural rubber or polyurethane for fine particles, mild acids/alkalis or corrosive slurry.

Shaft seal

Packing seal, expeller (dynamic) seal, mechanical seal, or expeller plus packing combination. Where seal water is used, its cleanliness, pressure and flow must be maintained.

This section describes general slurry pump principles, selection and maintenance. It does not constitute a commitment regarding particular product parameters, materials, service life or scope of service. Binding values are those in the supplied documentation and in documents confirmed in writing by both parties.
PERFORMANCE DATA

Performance data for 4/3D-AH

Clear-water data for this model, full series charts and notes from the manuals.

Model specification and technical parameters

ParameterValue / description
Suction bore4 in
Discharge bore3 in
Frame codeD (commonly published max. motor power about 60 kW)
Series codeAH
ConstructionHorizontal, overhung, double-casing centrifugal slurry pump
Wetted material optionsHigh-chrome wear alloys (often A05 / Cr26 / Cr27) for angular, highly abrasive solids; natural rubber or polyurethane for fine particles, mild acids/alkalis or corrosive slurry.
Shaft seal optionsPacking seal, expeller (dynamic) seal, mechanical seal, or expeller plus packing combination. Where seal water is used, its cleanliness, pressure and flow must be maintained.
Published series coverageTypical coverage: discharge bores about 25-450 mm, flow up to about 8600 m3/h and single-stage head up to about 68 m.

4/3D-AH · rows in AH Series Pump Performance Chart · table 1 (2)

ModelMax. power kWQ m³/hQ L/sH mn r/minMax. eff. %NPSH mImpeller mm
4/3D-AH6086.4-19824-559-521000-2200714-6245
4/3D-AH6079.2-18022-505-34.5800-1800593-5245

Full performance charts for this series

Complete clear-water performance data for this series. Click to expand; tables scroll horizontally.

AH Series Pump Performance Chart · table 135 rows
ModelMax. power kWQ m³/hQ L/sH mn r/minMax. eff. %NPSH mImpeller mm
1.5/1B-AH1512.6-28.83.5-86-681200-3800402-4152
2/1.5B-AH1532.4-729-206-581200-3200453.5-8184
3/2C-AH3039.6-86.411-2412-641300-2700554-6214
4/3C-AH3086.4-19824-559-521000-2200714-6245
4/3D-AH6086.4-19824-559-521000-2200714-6245
6/4D-AH60162-36045-10012-56800-1550655-8365
6/4E-AH120162-36045-10012-56800-1550655-8365
8/6E-AH120360-828100-23010-61500-1140722-9510
8/6R-AH300360-828100-23010-61500-1140722-9510
10/8ST-AH560612-1368170-38011-61400-850714-10686
12/10ST-AH560936-1980260-5507-68300-800826762
14/12ST-AH5601260-2772350-77013-63300-600773-10965
16/14TU-AH1201368-3060380-85011-63250-550794-101067
20/18TU-AH12002520-5400700-150013-57200-400855-101370
1.5/1B-AH1510.8-25.23-77-521400-3400352-4152
2/1.5B-AH1525.2-547-155.5-411000-2600502.5-5178
3/2C-AH3036-75.610-2113-391300-2100552-4213
4/3C-AH3079.2-18022-505-34.5800-1800593-5245
4/3D-AH6079.2-18022-505-34.5800-1800593-5245
6/4D-AH60144-32440-9012-45800-1350653-5365
6/4E-AH120144-32440-9012-45800-1350653-5365
8/6E-AH120324-72090-2007-49400-1000655-10510
8/6R-AH300324-72090-2007-49400-1000655-10510
10/8ST-AH560540-1188150-33012-50400-750754-12686
12/10ST-AH560720-1620200-4507-45300-650802.5-7.5762
14/12ST-AH5601152-2520320-70013-44300-500793-8965
16-14TU-AH12001224-2754340-7659-43250-450823-81067
20-18TU-AH12002268-4860630-135011-46200-350822-81372
10/8E-M120540-1440150-40014-60600-1000734-10549
10/8R-M300540-1440150-40014-60600-1000734-10549
1.5/1C-HH3016.2-34.24.5-9.525-921400-2200202-5.5330
3/2D-HH6068.4-136.819-3825-87850-1400473-7.5457
4/3E-HH120126-25235-7012-97600-1400502-5508
6/4F-HH260324-72090-20030-118600-1000643-8711
8/6S-HH560468-1008130-28020-94500-1000654-12711
Clear-water performance data for reference only; binding values follow the supplied technical documents and written confirmation.
FROM THE MANUAL

Notes from the product manuals

Compiled from the AH / L / G, SP, ZJ and ZGB pump manuals, with links to the full texts.

General construction, installation and operation

01 · Overview and scope

Horizontal slurry pumps are overhung centrifugal pumps for abrasive or corrosive slurry, widely used in metallurgy, mining, petrochemical, coal, power, dredging, building materials and municipal works. Families cover heavy duty (AH, HH), light duty (L), gravel / dredging (D, G) and rubber-lined (AHR, LR, MR) builds. Pumps may be staged in series within the allowable working pressure.

02 · Construction

Heavy duty AH and HH pumps use a double casing: an outer pressure-retaining casing and cover in grey or ductile iron, vertically split and bolted, plus replaceable wear liners (impeller, volute liner, throat bush and frame plate liner) in metal or rubber. The discharge can be rotated in eight positions at 45 degree intervals. D and G gravel pumps use a single casing with all wetted parts in wear-resistant metal. Apart from the wet end, all horizontal types share the same frame and bearing assembly, with a large-diameter shaft and short overhang.

03 · Assembly and installation

Preheat bearing inner rings to no more than 120 C during assembly and seat them firmly against the shaft shoulder or grease retainer. Inner rings, outer rings and spacers of double-row tapered roller bearings form a matched set and must not be interchanged. Wet-end assembly order: seals, frame plate liner with its locating nuts, impeller, volute liner clamped in place, then throat bush and cover plate. Lift crated pumps by the marked sling points without shock or excessive tilt; lifting eyes on the casing are for dismantling the casing only, never for lifting the complete pump.

04 · Shaft seal and lubrication

Three shaft seal arrangements are common: expeller, packed gland and mechanical seal. The expeller seal suits single-stage pumps (or the first stage of a series set) where inlet positive pressure is below 10 percent of discharge pressure; it needs no seal water and does not dilute the slurry. A packed gland is simple to service but requires seal water. A mechanical seal gives the best sealing and requires cooling water. A packed gland comprises the stuffing box, shaft sleeve, spacer, O-rings, packing, packing spacer, lantern ring and gland. Bearings are grease or oil lubricated, with oil lubrication preferred for high temperature or large pumps.

05 · Start-up and operation

Before start-up check that foundation and coupling bolts are tight, turn the shaft by hand in the direction of rotation without rubbing, verify motor rotation against the arrow on the casing, and align the V-belts square to the pulleys. Starting on clean water is preferable before slurry is introduced. During operation watch the instruments for flow, velocity and current and correct any abnormality. Where possible flush with clean water before stopping, then stop the pump before closing the valve. For vertical sump pumps, turn on the guide bearing flush water five minutes before starting and close it five minutes after stopping.

06 · Maintenance and faults

Check impeller-to-throatbush clearance, bearing temperature and lubrication, seal water pressure and flow, and wear of wetted parts on a regular basis. A worn impeller reduces flow and head and raises vibration and noise, so adjust the clearance or replace the wear parts. Typical faults are insufficient flow or head, bearing overheating, vibration, seal leakage and cavitation, usually caused by blockages, wrong rotation, low speed, air ingress on the suction side, inadequate NPSH or loss of dynamic balance. Record basic part numbers and material suffixes and verify them against the pump model and supplied documents.

Series-specific notes for AH Series Heavy Duty Slurry Pump

01

The fractional AH designation uses inlet / outlet diameters in inches (6/4 means a 6 inch inlet and 4 inch outlet). The casing registers on the frame and the discharge can be installed in eight positions.

02

Preheat bearing inner rings to no more than 120 C. R, S, ST, T, TU and U bearing assemblies use a double-row tapered roller bearing at the pump end whose axial clearance is preset and needs no adjustment.

03

The expeller seal applies where inlet positive pressure is no more than 10 percent of discharge pressure. Above 1 MPa or with corrosive slurry, PTFE-impregnated asbestos packing may be used.

Source text excerpts

Original manual text

Extracts from the original manuals are shown in the Chinese edition; the full texts are available via the links below.

Read the source documents online

WEAR PARTS

Wear parts for this series

Open each part page for function, material and replacement notes.

INQUIRY

4/3D-AH — quotation and part check

Send the model or worn-part dimensions, or call +86 188 0321 2220 / email sale@pumpq.com.

Request a price

We reply within one business day. You can also call +86 188 0321 2220.

Your details are used for this inquiry only.

Model and spare part identification

Please provide the pump model, nameplate data and duty parameters by phone or email. Performance charts and manuals can be read online.

Click outside or press Esc to close
☎Call✉Email⇄Inquiry