Shijiazhuang Zhongqian Pump Industry Co., Ltd. · Slurry pumps / Spare parts / Technical support
ZQZhongqian PumpZHONGQIAN PUMP
Home/Slurry Pumps/AF Series Froth Pump/AF
AF Series Froth Pump product sheet
AF Series Froth Pump product sheetModel AF
AF Series Froth Pump · Model details

AF

AF Series Froth Pump

The AF froth pump handles aerated, foam-prone flotation slurry. An enlarged suction arrangement and foam-inducing/de-aerating design reduce cavitation and loss of prime, typically in flotation circuits and chemical froth duties.

Gravel / Special PumpHorizontal froth slurry pump
MODEL CODE

Reading the code AF

Each segment explained against published industry naming conventions.

FieldMeaning
Model codeAF
NoteActual configuration follows supplied documents and written confirmation
Model codes are explained against common industry naming conventions for reading the letters and numbers only. Bore sizes, frames, materials and performance of a specific build follow the supplied documents and written confirmation.
CONSTRUCTION & DUTIES

Construction and typical duties

AF Series Froth Pump

Construction

01

Designed for aerated slurry to reduce cavitation and flow fluctuation.

02

Large suction inlet and wide passages help frothy slurry enter the pump.

03

Wetted parts in wear-resistant metal or rubber lining.

04

Usually integrated into flotation circuits; foam volume and liquid level are checked.

Typical duties

01

Flotation froth concentrate transfer

02

Aerated chemical slurry

03

Low-suction duties with foam-prone media

Construction drawing
Slurry pump construction drawing
MATERIALS & SEALS

Wetted materials and shaft seals

Wetted materials

High-chrome wear alloy or rubber lining, selected against particle characteristics and corrosiveness.

Shaft seal

Packing, expeller or mechanical seals according to site conditions.

This section describes general slurry pump principles, selection and maintenance. It does not constitute a commitment regarding particular product parameters, materials, service life or scope of service. Binding values are those in the supplied documentation and in documents confirmed in writing by both parties.
PERFORMANCE DATA

Performance data for AF

Clear-water data for this model, full series charts and notes from the manuals.

Model specification and technical parameters

ParameterValue / description
Model codeAF
NoteActual configuration follows supplied documents and written confirmation
ConstructionHorizontal froth slurry pump
Wetted material optionsHigh-chrome wear alloy or rubber lining, selected against particle characteristics and corrosiveness.
Shaft seal optionsPacking, expeller or mechanical seals according to site conditions.
Published series coveragePublished specifications are grouped by bore and flow class; exact figures follow written confirmation.

About the performance data for this model

Clear-water data for this particular model is not listed separately; the common coverage of its series is given below for reference only. Expand the full series charts where available. Binding values follow the supplied documents and written confirmation.

Commonly published series coverage

Published specifications are grouped by bore and flow class; exact figures follow written confirmation.

Clear-water performance data for reference only; binding values follow the supplied technical documents and written confirmation.
FROM THE MANUAL

Notes from the product manuals

Compiled from the AH / L / G, SP, ZJ and ZGB pump manuals, with links to the full texts.

General construction, installation and operation

01 · Overview and scope

Horizontal slurry pumps are overhung centrifugal pumps for abrasive or corrosive slurry, widely used in metallurgy, mining, petrochemical, coal, power, dredging, building materials and municipal works. Families cover heavy duty (AH, HH), light duty (L), gravel / dredging (D, G) and rubber-lined (AHR, LR, MR) builds. Pumps may be staged in series within the allowable working pressure.

02 · Construction

Heavy duty AH and HH pumps use a double casing: an outer pressure-retaining casing and cover in grey or ductile iron, vertically split and bolted, plus replaceable wear liners (impeller, volute liner, throat bush and frame plate liner) in metal or rubber. The discharge can be rotated in eight positions at 45 degree intervals. D and G gravel pumps use a single casing with all wetted parts in wear-resistant metal. Apart from the wet end, all horizontal types share the same frame and bearing assembly, with a large-diameter shaft and short overhang.

03 · Assembly and installation

Preheat bearing inner rings to no more than 120 C during assembly and seat them firmly against the shaft shoulder or grease retainer. Inner rings, outer rings and spacers of double-row tapered roller bearings form a matched set and must not be interchanged. Wet-end assembly order: seals, frame plate liner with its locating nuts, impeller, volute liner clamped in place, then throat bush and cover plate. Lift crated pumps by the marked sling points without shock or excessive tilt; lifting eyes on the casing are for dismantling the casing only, never for lifting the complete pump.

04 · Shaft seal and lubrication

Three shaft seal arrangements are common: expeller, packed gland and mechanical seal. The expeller seal suits single-stage pumps (or the first stage of a series set) where inlet positive pressure is below 10 percent of discharge pressure; it needs no seal water and does not dilute the slurry. A packed gland is simple to service but requires seal water. A mechanical seal gives the best sealing and requires cooling water. A packed gland comprises the stuffing box, shaft sleeve, spacer, O-rings, packing, packing spacer, lantern ring and gland. Bearings are grease or oil lubricated, with oil lubrication preferred for high temperature or large pumps.

05 · Start-up and operation

Before start-up check that foundation and coupling bolts are tight, turn the shaft by hand in the direction of rotation without rubbing, verify motor rotation against the arrow on the casing, and align the V-belts square to the pulleys. Starting on clean water is preferable before slurry is introduced. During operation watch the instruments for flow, velocity and current and correct any abnormality. Where possible flush with clean water before stopping, then stop the pump before closing the valve. For vertical sump pumps, turn on the guide bearing flush water five minutes before starting and close it five minutes after stopping.

06 · Maintenance and faults

Check impeller-to-throatbush clearance, bearing temperature and lubrication, seal water pressure and flow, and wear of wetted parts on a regular basis. A worn impeller reduces flow and head and raises vibration and noise, so adjust the clearance or replace the wear parts. Typical faults are insufficient flow or head, bearing overheating, vibration, seal leakage and cavitation, usually caused by blockages, wrong rotation, low speed, air ingress on the suction side, inadequate NPSH or loss of dynamic balance. Record basic part numbers and material suffixes and verify them against the pump model and supplied documents.

Series-specific notes for AF Series Froth Pump

01

Froth pumps handle aerated slurry; impeller and suction design favour gas separation and steady feed, often with a vertical tank or horizontal arrangement.

02

Provide froth factor, air content, solids concentration and sump level when selecting; do not apply ordinary slurry pump data directly.

Source text excerpts

Original manual text

Extracts from the original manuals are shown in the Chinese edition; the full texts are available via the links below.

Read the source documents online

WEAR PARTS

Wear parts for this series

Open each part page for function, material and replacement notes.

INQUIRY

AF — quotation and part check

Send the model or worn-part dimensions, or call +86 188 0321 2220 / email sale@pumpq.com.

Request a price

We reply within one business day. You can also call +86 188 0321 2220.

Your details are used for this inquiry only.

Model and spare part identification

Please provide the pump model, nameplate data and duty parameters by phone or email. Performance charts and manuals can be read online.

Click outside or press Esc to close
☎Call✉Email⇄Inquiry