The ZJL vertical pump shares its hydraulic design with the ZJ series. Part of the pump is submerged, driven by a vertical motor through an extended shaft, suiting washery and power plant floor wash-up and pit drainage.
Each segment explained against published industry naming conventions.
| Field | Meaning |
|---|---|
| Discharge bore | 150 mm |
| Series code | ZJL vertical slurry pump |
| Vane code | A (commonly 5 vanes) |
| Nominal impeller diameter | 35 cm |
ZJL Series Vertical Slurry Pump
Vertical mounting with a small footprint; mounts directly on a tank or steel structure.
Shares some wear parts with the ZJ series, simplifying spare parts holding.
No shaft seal or seal water, reducing potential leak paths.
Immersion depth and shaft length follow the liquid level.
Floor wash-up in coal washeries and power plants
Pit and sump slurry drainage
Vertical duties with modest level variation

High-chrome wear alloy wetted parts; rubber lining is evaluated where corrosion is present.
Usually seal-less; inspection focuses on guide bearings and submerged wear parts.
Clear-water data for this model, full series charts and notes from the manuals.
| Parameter | Value / description |
|---|---|
| Discharge bore | 150 mm |
| Series code | ZJL vertical slurry pump |
| Vane code | A (commonly 5 vanes) |
| Nominal impeller diameter | 35 cm |
| Construction | Vertical, single-stage single-suction submerged slurry pump |
| Wetted material options | High-chrome wear alloy wetted parts; rubber lining is evaluated where corrosion is present. |
| Shaft seal options | Usually seal-less; inspection focuses on guide bearings and submerged wear parts. |
| Published series coverage | Published sizes are combinations of bore, impeller diameter and speed; exact values follow written confirmation. |
| Model | Max. motor kW | Q m³/h | H m | n r/min | Eff. % | NPSH m | Max. particle mm | Weight kg |
|---|---|---|---|---|---|---|---|---|
| 150ZJL-A35 | 37 | 99-364 | 3.0-17.9 | 490-980 | 69.0 | / | 15 | 800 |
Complete clear-water performance data for this series. Click to expand; tables scroll horizontally.
| Model | Max. motor kW | Q m³/h | H m | n r/min | Eff. % | NPSH m | Max. particle mm | Weight kg |
|---|---|---|---|---|---|---|---|---|
| 150ZJL-B55B | 110 | 128.5-479.1 | 10.0-49.3 | 490-980 | 59.8 | / | 50 | 2112 |
| 150ZJL-A35 | 37 | 99-364 | 3.0-17.9 | 490-980 | 69.0 | / | 15 | 800 |
| 100ZJL-A34 | 45 | 74-293 | 5.5-36.8 | 700-1480 | 65.8 | / | 14 | 630 |
| 80ZJL-A36 | 45 | 50-201 | 7.3-45.5 | 700-1480 | 58.2 | / | 12 | 650 |
| 80ZJL-A36B | 45 | 51.1-220.5 | 6.4-44.9 | 700-1480 | 54.1 | / | 15 | 650 |
| 65ZJL-A30 | 18.5 | 18-98 | 5.9-34.7 | 700-1470 | 53.7 | / | 8 | 440 |
| 65ZJL-A30B | 22 | 27.9-105.8 | 7.1-34.4 | 700-1470 | 60.9 | / | 10 | 440 |
| 65ZJL-B30J | 15 | 18.9-84.2 | 5.8-32.3 | 700-1470 | 49.1 | / | 8 | 440 |
| 50ZJL-A45B | 55 | 22.9-107.4 | 11.4-74.0 | 700-1470 | 39.1 | / | 25 | 1106 |
| 50ZJL-B40 | 30 | 15-65 | 8.6-58.3 | 700-1470 | 34.1 | / | 9 | 540 |
| 50ZJL-A35 | 22 | 19-86 | 7.3-47.1 | 700-1470 | 48.1 | / | 15 | 500 |
| 50ZJL-A35B | 22 | 17.1-73 | 8.0-46.5 | 700-1470 | 45.1 | / | 20 | 500 |
| 50ZJL-A20 | 4 | 8-38 | 1.4-10.7 | 700-1470 | 38.6 | / | 10 | 240 |
| 50ZJL-A20J | 30 | 18-70 | 5.6-46.2 | 1440-2950 | 33.8 | / | 22 | 570 |
| 40ZJL-A35 | 18.5 | 9.4-47.6 | 8.1-48.0 | 700-1470 | 38.7 | / | 7 | 500 |
| 40ZJL-B25 | 4 | 4.9-22.9 | 4.0-21.5 | 700-1440 | 37.6 | / | 8 | 225 |
| 40ZJL-B25B | 5.5 | 4.9-24.2 | 3.5-19.1 | 700-1440 | 30.4 | / | 8 | 225 |
| 40ZJL-A21 | 4 | 4.6-25.9 | 3.3-17.0 | 700-1440 | 44.6 | / | 10 | 210 |
| 40ZJL-A21B | 4 | 5.8-25.2 | 2.5-14.6 | 700-1440 | 36.6 | / | 10 | 210 |
Compiled from the AH / L / G, SP, ZJ and ZGB pump manuals, with links to the full texts.
Horizontal slurry pumps are overhung centrifugal pumps for abrasive or corrosive slurry, widely used in metallurgy, mining, petrochemical, coal, power, dredging, building materials and municipal works. Families cover heavy duty (AH, HH), light duty (L), gravel / dredging (D, G) and rubber-lined (AHR, LR, MR) builds. Pumps may be staged in series within the allowable working pressure.
Heavy duty AH and HH pumps use a double casing: an outer pressure-retaining casing and cover in grey or ductile iron, vertically split and bolted, plus replaceable wear liners (impeller, volute liner, throat bush and frame plate liner) in metal or rubber. The discharge can be rotated in eight positions at 45 degree intervals. D and G gravel pumps use a single casing with all wetted parts in wear-resistant metal. Apart from the wet end, all horizontal types share the same frame and bearing assembly, with a large-diameter shaft and short overhang.
Preheat bearing inner rings to no more than 120 C during assembly and seat them firmly against the shaft shoulder or grease retainer. Inner rings, outer rings and spacers of double-row tapered roller bearings form a matched set and must not be interchanged. Wet-end assembly order: seals, frame plate liner with its locating nuts, impeller, volute liner clamped in place, then throat bush and cover plate. Lift crated pumps by the marked sling points without shock or excessive tilt; lifting eyes on the casing are for dismantling the casing only, never for lifting the complete pump.
Three shaft seal arrangements are common: expeller, packed gland and mechanical seal. The expeller seal suits single-stage pumps (or the first stage of a series set) where inlet positive pressure is below 10 percent of discharge pressure; it needs no seal water and does not dilute the slurry. A packed gland is simple to service but requires seal water. A mechanical seal gives the best sealing and requires cooling water. A packed gland comprises the stuffing box, shaft sleeve, spacer, O-rings, packing, packing spacer, lantern ring and gland. Bearings are grease or oil lubricated, with oil lubrication preferred for high temperature or large pumps.
Before start-up check that foundation and coupling bolts are tight, turn the shaft by hand in the direction of rotation without rubbing, verify motor rotation against the arrow on the casing, and align the V-belts square to the pulleys. Starting on clean water is preferable before slurry is introduced. During operation watch the instruments for flow, velocity and current and correct any abnormality. Where possible flush with clean water before stopping, then stop the pump before closing the valve. For vertical sump pumps, turn on the guide bearing flush water five minutes before starting and close it five minutes after stopping.
Check impeller-to-throatbush clearance, bearing temperature and lubrication, seal water pressure and flow, and wear of wetted parts on a regular basis. A worn impeller reduces flow and head and raises vibration and noise, so adjust the clearance or replace the wear parts. Typical faults are insufficient flow or head, bearing overheating, vibration, seal leakage and cavitation, usually caused by blockages, wrong rotation, low speed, air ingress on the suction side, inadequate NPSH or loss of dynamic balance. Record basic part numbers and material suffixes and verify them against the pump model and supplied documents.
ZJL pumps comprise impeller, volute, frame plate liner, shaft sleeve, support column, mounting plate, shaft, bearings and bearing housing. The impeller, volute and frame plate liner are high-chrome wear alloy and the pump has no shaft seal.
The digits denote discharge diameter and nominal impeller diameter and the letter denotes the vane code. Ensure the mounting plate sits flat on the foundation.
Extracts from the original manuals are shown in the Chinese edition; the full texts are available via the links below.
Open each part page for function, material and replacement notes.
Models, parts and manuals related to this product.
Send the model or worn-part dimensions, or call +86 188 0321 2220 / email sale@pumpq.com.
We reply within one business day. You can also call +86 188 0321 2220.
Please provide the pump model, nameplate data and duty parameters by phone or email. Performance charts and manuals can be read online.