Identify parts by basic number
Impeller, frame plate liner, casing, shaft sleeve and more, each with basic number, bilingual name, location, materials (high-chrome alloy / rubber / 3Cr13), wear signs and service notes, with links to matching pump models.

Four wetted and seal parts most often identified, with materials and basic numbers on their own pages.

The impeller is the energy-converting core of a slurry pump. It transfer…

The frame plate liner protects the drive-side casing from erosion and fo…

The casing carries system pressure and locates the pump end and frame. I…

The shaft sleeve fits over the pump shaft and isolates it from packing f…
Switch between wetted, seal, drive and fastener groups to see materials and basic numbers.
Balance abrasion and corrosion resistance against the medium.
| Material | Typical duty | Selection notes |
|---|---|---|
| High chrome alloy Cr26 / Cr27 / Cr30 | Coarse, sharp, highly abrasive ore slurry, tailings and ash | Very hard and abrasion resistant; relatively brittle and not suited to large stray impacts |
| Natural / synthetic wear-resistant rubber | Fine particles, mildly acidic or alkaline corrosive slurry; noise and vibration damping | Elastic and resistant to fine-particle cutting; vulnerable to sharp coarse solids and high temperature - check the temperature limit |
| Duplex stainless / high-nickel alloy | Strongly corrosive, chloride-bearing or high-temperature specialty slurries | Corrosion resistance first; weigh service life and cost against abrasiveness |
| Polyurethane / ceramic composite | Fine but highly abrasive particles, or lightweight wear solutions | Lightweight and wear resistant, higher cost; always verify part number and dimensions |
The seal option determines seal-water demand and the wear part set.
Simple and easy to service on site. A small controlled drip lubricates and cools the packing, so a reliable sealing-water supply is needed. Common on general duties.
The expeller generates back pressure to balance the pressure at the seal, reducing sealing-water demand. Widely used on tailings and ash duties.
Very low leakage for duties where spillage is unacceptable or the medium is hazardous; demands accurate installation and a clean flush-water system.
Use the drawings to identify part positions and assembly relationships.






Following this order before ordering reduces mismatches.
Then open the part page for location and wear notes.
Then open the part page for location and wear notes.
Then open the part page for location and wear notes.
Then open the part page for location and wear notes.
Then open the part page for location and wear notes.
Then open the part page for location and wear notes.
Please provide the pump model, nameplate data and duty parameters by phone or email. Performance charts and manuals can be read online.